Command codes for the USB-1208FS Daq.
0x10 16
DaqAIn Read analog in
0x11 17
DaqAInScan Read analog in, clocked
0x12 18
DaqAInStop Stop input scan
0x13 19
DaqALoadQueue Set channel gains
0x14 20
DaqAOut Write analog out
0x15 21
DaqAOutScan Write analog out, clocked
0x16 22
DaqAOutStop Stop output scan
0x01 1
DaqDConfigPort Configure digital port
0x03 3
DaqDIn Read digital ports
0x04 4
DaqDOut Write digital port
0x40 64
DaqBlinkLED Cause LED to blink
0x20 32
DaqCInit Initialize counter
0x21 33
DaqCIn Read counter
0x46 70
DaqGetAll Read all analog and digital input values
0x44 68
DaqGetStatus Read device status
0x41 65
DaqReset Reset the device
0x45 69
DaqSetCal Set CAL output
0x43 67
DaqSetSync Configure sync
0x42 66
DaqSetTrigger Configure ext. trigger
0x30 48
DaqMemRead Read memory
0x31 49
DaqMemWrite Write memory
0x55 85
DaqReadCode Read program memory
0x50 80
DaqPrepareDownload Prepare for program memory download
0x51 81
DaqWriteCode Write program memory
0x53 83
DaqWriteSerialNumber Write a new serial number to device
See also Daq,
DaqFunctions,
DaqPins.
Command codes for USB-1608FS. Since all overlapped codes are the same,
assume that all codes are the same... well... except that there are no
analog output ports apparently, so
DaqAOut,
DaqAOutScan, and
DaqAOutStop
should not have associated codes. No 20, 21, or 22.
0x01 1
DaqDConfigPort Configure digital port
0x02 2
DaqDConfigPortBit Configure individual digital port bits
0x03 3
DaqDIn Read digital port
0x04 4
DaqDOut Write digital port
0x05 5
DaqDReadBit Read digital port bit
0x06 6
DaqDWriteBit Write digital port bit
0x10 16
DaqAIn Read analog input channel
0x11 17
DaqAInScan Scan analog channels
0x12 18
DaqAInStop Stop input scan
0x13 19
DaqALoadQueue Load the channel/gain queue
0x20 32
DaqCInit Initialize counter
0x21 33
DaqCIn Read Counter
0x30 48
DaqMemRead Read Memory
0x31 49
DaqMemWrite Write Memory
0x40 64
DaqBlinkLED Causes LED to blink
0x41 65
DaqReset Reset USB interface
0x42 66
DaqSetTrigger Configure external trigger
0x43 67
DaqSetSync Configure sync input/output
0x44 68
DaqGetStatus Get device status
0x45 69
DaqSetCal Set calibration output
0x46 70
DaqGetAll Get all analog and digital input values
0x50 80
DaqPrepareDownload Prepare for program memory download
0x51 81
DaqWriteCode Write program memory
0x52 82 (unwritten) Return program memory checksum
0x53 83
DaqWriteSerialNumber Write a new serial number to device
0x54 84 (unwritten) Update program memory
0x55 85
DaqReadCode Read program memory
Command codes for USB-1024LS and similar: Quite different from the 1x08
series: A speciality is that reportId must be always zero (0) for these
devices - they use interrupt endpoint 0 transfers. For the same reason,
output reports must always by 8 bytes in length -- pad them if they're
shorter! Handling of port C of the device may be a bit quirky, as it is
treated as two ports, a low port and a high port.
This is based on code and command codes found in usb-1024LS.h and .c,
subroutine files of the free libhid, a GPL'ed cross platform HID device
library written by Warren Jasper (<wjasper@tx.ncsu.edu>). It has not been
tested by me on any actual device! (MK).
0x0d 13
DaqDConfigPort Configure digital port (portid == portA = 0x1, portB = 0x4, portClow = 0x8 portCHi = 0x2)
0x03 3
DaqDIn Read digital port
0x01 1
DaqDOut Write digital port
0x02 2
DaqDReadBit Read digital port bit (unwritten)
0x03 3
DaqDWriteBit Write digital port bit (unwritten)
0x0b 11
DaqBlinkLED Causes LED to blink
0x11 17
DaqReset Reset USB interface (unwritten)
0x05 5
DaqCInit Initialize counter
0x04 4
DaqCIn Read Counter
0x0a 10
DaqWriteCode Write program memory (unwritten)
0x09 9
DaqReadCode Read program memory (unwritten)
0x0c 12
DaqWriteSerialNumber Write a new serial number to device (unwritten)